Keep your cleanroom in class, and your line running.

A cleanroom keeps airborne particles under a set limit: its class. Plain answers on classes, gowning, cleaning and retests in Malaysia, and a trained crew when your room needs work.

Checked against ISO 14644-1:2015 and EU GMP Annex 1.

Crews in Penang, Kulim, Johor and the Klang Valley.

A wide, bright cleanroom with a perforated grey floor; a gowned technician works on polished steel, two more work behind
3,520ISO 5

The most particles of 0.5 µm or larger allowed in each m³ of air.

  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9

SRF Test Lab cleanroom, Jefferson Lab, Virginia. Public domain.Limit: ISO 14644-1:2015, Table 1.

What keeps a room in class

5 short guides. Each one checked against the standard it sums up.

How often to prove the class

The longest gap between particle counts, by class. ISO 14644-2:2015.

Retest coming up? We count the room first, so the tester finds no surprises.

Ask about a count

Particle retest: at least every 6 months for ISO 5 and cleaner; at least every 12 months for ISO 6 to ISO 9.

The classes most plants use

A class is the most particles of 0.5 µm and larger allowed in one m³ of air. Each class up allows ten times more.

ClassParticles ≥ 0.5 µm per m³1,00010,000100,0001,000,000GMP gradeOften used for
ISO 5Class 100
3,520
GMP: Grade A; Grade B at rest
The critical zone: sterile filling, laminar flow benches, wafer handling
ISO 6Class 1,000
35,200
GMP: None
Chip assembly, optics
ISO 7Class 10,000
352,000
GMP: Grade C at rest; Grade B in operation
Medical device assembly, pharmacy compounding, electronics
ISO 8Class 100,000
3,520,000
GMP: Grade D at rest; Grade C in operation
Gowning rooms, packaging, electronics assembly
Source: ISO 14644-1:2015 Table 1; EU GMP Annex 1 (2022). The scale is logarithmic: each mark is ten times the last.All nine classes

Where Malaysia's cleanrooms are

Four places hold most of the country's cleanrooms. Our crews work in all four.

PenangBayan Lepas, Batu Kawan

Chip assembly and test, and the equipment makers that supply them.

Kulim, KedahKulim Hi-Tech Park

Infineon's silicon carbide fab, AT&S substrates and Ferrotec.

JohorJohor Bahru, Pasir Gudang, Senai

Electronics and medical device plants.

Klang ValleySelangor and Kuala Lumpur

Medicine and medical device makers, under NPRA's GMP and the Medical Device Authority's rules.

What our crews do

Three jobs that keep a room in class between retests.

  • Cleaning

    Crews gowned and trained for your class. Clean to dirty, top to bottom.

    1. Ceiling
    2. Walls
    3. Equipment
    4. Floor
    Every shift or every week
  • Supplies

    Wipers, IPA, gloves, smocks and tape, matched to your class.

    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    6. 6
    7. 7
    8. 8
    9. 9
    ISO 5 to ISO 8, GMP A to D
  • Testing

    We count the room before your tester comes. No surprises on the day.

    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    6. 6
    7. 7
    8. 8
    9. 9
    10. 10
    11. 11
    12. 12
    Our count in month 11. Your retest in month 12.
A bright white cleanroom; one gowned engineer looks into a microscope, another checks a part at a steel cabinet

A room in class at every retest.

Tell us three things. We say what the room needs, and send a crew trained to its class.

Email or phone: one is enough.

Asking is free. You get a plain answer, not a sales call. We use your details only to answer you.

Questions

What is a cleanroom?

A room that holds airborne particles under a set limit. Filtered air (HEPA or ULPA), steady pressure, controlled airflow and gowned staff keep it there. ISO 14644-1 sets the limits as classes.

Which cleanroom class do I need?

Your process, your customer or your regulator sets it. Electronics assembly often runs at ISO 7 or ISO 8. Sterile filling needs GMP Grade A (ISO 5) where the product is open. Wafer fabs run ISO 5 or cleaner around the wafer. See cleanroom classes.

Is ISO 14644 the law in Malaysia?

No. ISO 14644 is a standard, not a law. Medicine makers must meet GMP, which NPRA enforces and which classifies rooms by ISO 14644. Electronics and device plants meet it because their customers ask for it. See ISO 14644.

Can you clean, supply or test my cleanroom?

Yes. Tell us the class, the size and the town. We say what the room needs and send a crew trained to its class. Ask about your cleanroom.

What is a Class 100 or Class 10,000 cleanroom?

The old US names (FED-STD-209E, cancelled in 2001). Class 100 is ISO 5. Class 10,000 is ISO 7. Class 100,000 is ISO 8.