Keep your cleanroom in class, and your line running.
A cleanroom keeps airborne particles under a set limit: its class. Plain answers on classes, gowning, cleaning and retests in Malaysia, and a trained crew when your room needs work.
Checked against ISO 14644-1:2015 and EU GMP Annex 1.
Crews in Penang, Kulim, Johor and the Klang Valley.

The most particles of 0.5 µm or larger allowed in each m³ of air.
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
SRF Test Lab cleanroom, Jefferson Lab, Virginia. Public domain.Limit: ISO 14644-1:2015, Table 1.
What keeps a room in class
5 short guides. Each one checked against the standard it sums up.

Classes
ISO 1 to 9, the old Class 100 names, and the GMP grades.

Gowning
What to wear for each class, and the order to put it on.

Cleaning
Clean to dirty, top to bottom, and how often per class.
AI-generated imageISO 14644
The standard, part by part, and how a room is classified.
AI-generated imageConsumables
Wipers, IPA, tape, mops and gloves, by class.
How often to prove the class
The longest gap between particle counts, by class. ISO 14644-2:2015.
Retest coming up? We count the room first, so the tester finds no surprises.
Ask about a countParticle retest: at least every 6 months for ISO 5 and cleaner; at least every 12 months for ISO 6 to ISO 9.
The classes most plants use
A class is the most particles of 0.5 µm and larger allowed in one m³ of air. Each class up allows ten times more.
Where Malaysia's cleanrooms are
Four places hold most of the country's cleanrooms. Our crews work in all four.
Chip assembly and test, and the equipment makers that supply them.
Infineon's silicon carbide fab, AT&S substrates and Ferrotec.
Electronics and medical device plants.
Medicine and medical device makers, under NPRA's GMP and the Medical Device Authority's rules.
What our crews do
Three jobs that keep a room in class between retests.
- Cleaning
Crews gowned and trained for your class. Clean to dirty, top to bottom.
- Ceiling
- Walls
- Equipment
- Floor
- Supplies
Wipers, IPA, gloves, smocks and tape, matched to your class.
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- Testing
We count the room before your tester comes. No surprises on the day.
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12

A room in class at every retest.
Tell us three things. We say what the room needs, and send a crew trained to its class.
Questions
What is a cleanroom?
A room that holds airborne particles under a set limit. Filtered air (HEPA or ULPA), steady pressure, controlled airflow and gowned staff keep it there. ISO 14644-1 sets the limits as classes.
Which cleanroom class do I need?
Your process, your customer or your regulator sets it. Electronics assembly often runs at ISO 7 or ISO 8. Sterile filling needs GMP Grade A (ISO 5) where the product is open. Wafer fabs run ISO 5 or cleaner around the wafer. See cleanroom classes.
Is ISO 14644 the law in Malaysia?
No. ISO 14644 is a standard, not a law. Medicine makers must meet GMP, which NPRA enforces and which classifies rooms by ISO 14644. Electronics and device plants meet it because their customers ask for it. See ISO 14644.
Can you clean, supply or test my cleanroom?
Yes. Tell us the class, the size and the town. We say what the room needs and send a crew trained to its class. Ask about your cleanroom.
What is a Class 100 or Class 10,000 cleanroom?
The old US names (FED-STD-209E, cancelled in 2001). Class 100 is ISO 5. Class 10,000 is ISO 7. Class 100,000 is ISO 8.