ISO 14644: the cleanroom standard

ISO 14644 is the international standard for cleanrooms. Part 1 sets the classes. Part 2 says how often to prove them. Part 3 gives the tests. The other parts cover design, operations, chemicals and surfaces.

Reading time
3 min
Checked
20 November 2026
A ceiling HEPA filter with a perforated steel face, set in a white cleanroom ceiling beside a light panelAI-generated image
A ceiling filter: the clean air every class is counted in.

The parts

Part What it covers
14644-1 Classification of air cleanliness by particle concentration. The nine classes.
14644-2 Monitoring: how often to prove a room still meets its class.
14644-3 Test methods: particle counts, airflow, pressure, filter leaks, recovery.
14644-4 Design, construction and start-up.
14644-5 Operations: people, gowning, cleaning, materials in and out.
14644-7 Separative devices: clean air hoods, glove boxes, isolators, minienvironments.
14644-8 Air cleanliness by chemical concentration (AMC).
14644-9 Surface cleanliness by particle concentration.
14644-10 Surface cleanliness by chemical concentration.
14644-12 Monitoring air cleanliness by nanoscale particles.
14644-13 Cleaning surfaces to a set particle or chemical level.
14644-14 Whether equipment is fit for a class, by the particles it gives off.
14644-15 Whether equipment and materials are fit, by the chemicals they give off.
14644-16 Energy efficiency in cleanrooms and separative devices.
14644-17 Particle deposition rate.
14644-18 Whether consumables are fit for use.

Parts 1 to 3 are the ones every classified room uses. Check the current edition of each part at iso.org.

How a room is classified (ISO 14644-1)

  1. Agree the class, the particle sizes to count, and the state: as-built (empty), at-rest (equipment in, no people) or operational.
  2. Set the number of sample locations from the floor area, using Table A.1 of the standard. A larger room needs more locations.
  3. At each location, sample enough air to count at least 20 particles at the class limit for the largest size. Never less than 2 litres or 1 minute.
  4. Pass only if every location is at or under the limit for every size. The 2015 edition dropped the 95% confidence limit the 1999 edition used.
  5. Write it up: class, state, sizes, locations, results and the counter’s calibration.

How often to retest (ISO 14644-2)

Test Most time between tests
Particle count, ISO 5 and cleaner 6 months
Particle count, ISO 6 to ISO 9 12 months
Airflow volume or velocity 12 months
Air pressure difference 12 months

Source: ISO 14644-2:2015. Between tests, the standard expects a written monitoring plan based on risk. Filter leak, airflow pattern and recovery tests follow ISO 14644-3 at intervals your plan sets.

Questions

What is the latest version of ISO 14644-1?

ISO 14644-1:2015, the second edition. It replaced the 1999 edition and changed how many locations you sample and how results are judged.

Is FED-STD-209E still valid?

No. The US government cancelled it in 2001 and pointed users to ISO 14644-1. Plants still say "Class 100" or "Class 10,000" out of habit. See how the old names map to ISO classes.

Who certifies a cleanroom in Malaysia?

An independent test company runs the ISO 14644-3 tests and issues a report with the class. Ask for the particle counter's calibration certificate (ISO 21501-4) and the tester's training record.

Where do I get the standard?

Buy each part from ISO at iso.org. This site summarises it; the full text decides.