Cleanroom classes: ISO 1 to ISO 9

A class is the most particles allowed in one cubic metre of air, at set sizes. ISO 1 is the cleanest and ISO 9 the least clean. Each class up allows ten times more particles.

Reading time
3 min
Checked
20 November 2026
A white robot arm in a bright factory cleanroom
BBS Automation cleanroom, Blaichach, Germany. Clemenspool, CC0.

The limits

Particles per cubic metre, at or above each size. A dot means the standard sets no limit there.

Class 0.1 µm 0.2 µm 0.3 µm 0.5 µm 1 µm 5 µm
ISO 1 10 2
ISO 2 100 24 10 4
ISO 3 1,000 237 102 35 8
ISO 4 10,000 2,370 1,020 352 83
ISO 5 100,000 23,700 10,200 3,520 832
ISO 6 1,000,000 237,000 102,000 35,200 8,320 293
ISO 7 352,000 83,200 2,930
ISO 8 3,520,000 832,000 29,300
ISO 9 35,200,000 8,320,000 293,000

Source: ISO 14644-1:2015 Table 1. The limit for class N at size D µm is 10N × (0.1 / D)2.08, rounded to three figures.

Old names: Class 100 to Class 100,000

The US standard FED-STD-209E counted particles of 0.5 µm and larger per cubic foot. It was cancelled in 2001, but the names stuck.

Old name ISO class
Class 1 ISO 3
Class 10 ISO 4
Class 100 ISO 5
Class 1,000 ISO 6
Class 10,000 ISO 7
Class 100,000 ISO 8

GMP grades A to D

Medicine makers use grades, not classes. Each grade has a limit at rest and a looser one in operation.

Grade At rest In operation Used for
Grade A ISO 5 ISO 5 Open sterile product: filling, stoppering, aseptic connections
Grade B ISO 5 ISO 7 The room around a Grade A zone
Grade C ISO 7 ISO 8 Less critical steps, such as preparing solutions to be filtered
Grade D ISO 8 Set by the maker Handling parts after washing

Source: EU GMP Annex 1 (2022), which PIC/S adopted. Malaysia is a PIC/S member; NPRA inspects to it.

What each class is used for

Class Often used for
ISO 4 Wafer lithography; minienvironments around wafers
ISO 5 The critical zone: sterile filling, laminar flow benches, wafer handling
ISO 6 Chip assembly, optics
ISO 7 Medical device assembly, pharmacy compounding, electronics
ISO 8 Gowning rooms, packaging, electronics assembly

Typical uses, not rules. Your process, customer or regulator sets the class.

Questions

What is a 10K cleanroom?

A Class 10,000 room under the old US standard: no more than 10,000 particles of 0.5 µm and larger per cubic foot. Today that is ISO 7.

Is ISO 8 the same as Class 100,000?

Close enough to use as one. ISO 8 allows 3,520,000 particles of 0.5 µm and larger per cubic metre. Class 100,000 allowed 100,000 per cubic foot, about 3,530,000 per cubic metre.

Which is cleaner, ISO 7 or ISO 8?

ISO 7. It allows ten times fewer particles than ISO 8: 352,000 against 3,520,000 per cubic metre at 0.5 µm.

What is the cleanest cleanroom class?

ISO 1. Few rooms run it. Wafer fabs use ISO 3 to ISO 5 around the wafer, often inside a minienvironment rather than the whole room.